2001–2003 RAD Data Communications Ltd. Specifications are subject to change without prior notice.
All other trademarks are the property of their respective holders.
data communications
www.rad.com
International Headquarters
24 Raoul Wallenberg
Street
Tel Aviv 69719, Israel
Tel: (972) 3-6458181
Fax: (972) 3-6498250, 6474436
U.S. Headquarters
900 Corporate Drive
Mahwah, NJ 07430
Tel: (201) 529-1100
Toll free: 1-800-444-7234
Fax: (201) 529-5777
Vmux-110
Voice Trunking Gateway
185-100-10/03
Receive Signal Level
With CSU: 0 to -36 dB
Without CSU: 0 to -30 dB
Transmit Signal Level
With CSU: 0, -7.5, -15, or -22.5dB
Without CSU: ±2.7V (±10%) at
0-655 ft
Jitter Performance
Per AT&T TR-62411
Line Type
Balanced 4-wire, 100
Connector
RJ-45
FXS Analog Voice Ports
Number of Ports
4
Analog Parameters
ITU-T standards: G.713, 2-wire
for voice and signaling.
Nominal level : 0 dBm
Nominal impedance : 600
Return loss (300 to 3400 Hz):
better than 20 dB
Frequency response (Ref: 1020 Hz):
300 to 3000 Hz: ±0.5 dB
250 to 3400 Hz: ±1.1 dB
Level adjustment, soft selectable:
TX: +5 dBm to -10 dBm
RX: +5 dBm to -10 dBm
Steps: 2 dB (±0.1 dB), nominal
Signal to total distortion, G.712,
G.713 method 2:
0 to -30 dBm0: better than 33dB
+3 to -45 dBm0: better than 22dB
Idle channel noise: better than
-70 dBm0 (+20 dBrnc)
Signaling
EIA RS-464 Loop-Start
On-Hook/Off-Hook Threshold:
3V to 24V between TIP and
RING at off-hook state
Higher than 25V between TIP
and RING at on-hook state
Feed Current:
24 mA ±10%
Ringer:
Voltage: 50 VRMS (±10%),
overload protected
Frequency: 25 Hz (±10%)
Cadence: 1 sec ON / 3 sec OFF
(default), user-configurable
Connectors (per port)
RJ-11
CONTROL PORT
Standards
RS-232/V.24 (DCE)
Data Rate
9.6, 19.2, 38.4, 57.6 or
115.2 kbps
Connector
RJ-45
GENERAL
Diagnostics
Ethernet Ports:
Performance monitoring, LAN
statistics, PING
E1/T1 Voice Ports:
Local and Remote Loops on
entire E1/T1
Tone injection per timeslot
towards local side
FXS Voice Ports:
Local and Remote Loops per
channel
Tone injection per channel
towards local side
Indicators
PWR (green) – Indicates when
power is on
ETH (green) – ON when Ethernet
line is O.K.
ALM (red) – Indicates alarm is
present in system
Physical
Height: 4.3 cm/1.7 in
Width: 21.5 cm/8.5 in
Depth: 23.7 cm/9.3 in
Weight: 2.0 kg/4.4 lb
Power
(according to ordering)
Input:
AC: 100 to 240 VAC, 50/60 Hz
48: -36 to -72 VDC
Consumption:
4FXS: AC: 13.5W;
DC: 12.5W
E1/T1: AC: 10.2W;
DC: 9.0W
Environment
Operating temperature:
0 to 50°C/32 to 122°F
Storage temperature:
-20 to 70°C/-4 to 158°F
Humidity: Up to 90%,
non-condensing
ORDERING
VMUX-110/*/+/ETH-UTP
Voice Trunking Gateway
*
Specify power supply:
AC for 100 to 240 VAC
48 for -48 (-36 to -72) VDC
+ Specify voice port type:
E1/~
for E1 digital voice port
T1/~ for T1 digital voice port
4FXS for 4 analog FXS ports
~
Specify number of channels
supported by digital voice port:
6 for up to 6 channels
12 for up to 12 channels
18 for up to 18 channels
24
for up to 24 channels
30 for up to 30 channels (E1 only)
CBL-VM110/?
Serial link adaptor cable
? Specify interface and clock mode:
V35/DCE for V.35, DCE mode
V35/DTE for V.35, DTE mode
X21/DCE for X.21, DCE mode
X21/DTE for X.21, DTE mode
530/DTE for RS-530, DTE mode
Note:
An adaptor cable is not required for
connecting to RS-530 equipment when
Vmux-110 operates in DCE clock mode.
RM-35
Hardware for mounting one or two
Vmux-110 units in a 19-inch rack